Numerically Controlled Oscillator
In this tutorial we will demonstrate how to use the numerically controlled oscillator (NCO) during an experiment by: 1. Changing the modulation frequency, e.g. for rapid spectroscopy measurements 2. Setting the phase, e.g. for virtual \(Z\) gates
This tutorial has multiple sections showcasing how the hardware behaves in certain edge cases. These are optional and can be skipped.
We will show this by using a QRM and directly connecting outputs \(\text{O}^{[1-2]}\) to inputs \(\text{I}^{[1-2]}\) respectively. We will then use the QRM’s sequencers to sequence waveforms on the outputs and simultaneously acquire the resulting waveforms on the inputs.
To run this tutorial please make sure you have installed and enabled ipywidgets:
pip install ipywidgets
jupyter nbextension enable --py widgetsnbextension
Getting Started
How the NCO works
Modulation
The NCO modulates any AWG output at a certain frequency, such that we only need to store the envelope of any waveform to create a wave with the correct frequency and phase. To enable IQ up- and downconversion to RF frequencies, the device will generate a phase shifted signal on both signal paths. If modulation is enabled, the value of the NCO will be multiplied with the awg output and forwarded to path 0/1 as follows:
\begin{equation*} \text{path}_{0, \text{out}} = \frac{1}{\sqrt{2}}(\cos(\omega t)\text{awg}_0+\sin(\omega t)\text{awg}_1) \tag{1} \end{equation*}
\begin{equation*} \text{path}_{1, \text{out}} = \frac{1}{\sqrt{2}}(-\sin(\omega t)\text{awg}_0+\cos(\omega t)\text{awg}_1) \tag{2} \end{equation*}
Note the factor \(\sqrt{2}\), which is required to preserve the total signal amplitude and prevents clipping. These two outputs can then be used within a QRM-RF module or by an external mixer to generate RF pulses.
Demodulation
Usually, we are interested in the envelope of the acquired signal instead of the oscillating values, in particular when integrating. Therefore, the NCO can also be used to demodulate the signal before integration. If demodulation is enabled, the signal is again multiplied with the NCO, this time with a prefactor \(\sqrt{2}\). Thus, if we modulate and demodulate the same signal, we obtain the original awg output:
\begin{equation*} \text{path}_{0, \text{in}} = \sqrt{2}(\cos(\omega t)\text{in}_0-\sin(\omega t)\text{in}_1) = \cos(\omega t)\cos(\omega t)\text{awg}_0+\sin(\omega t)\sin(\omega t)\text{awg}_0 = \text{awg}_0 \tag{3} \end{equation*}
\begin{equation*} \text{path}_{1, \text{in}} = \sqrt{2}(\cos(\omega t)\text{in}_1+\sin(\omega t)\text{in}_0) = \cos(\omega t)\cos(\omega t)\text{awg}_1+\sin(\omega t)\sin(\omega t)\text{awg}_1 = \text{awg}_1 \tag{4} \end{equation*}
Setup
First, we are going to import the required packages and connect to the instrument.
[1]:
# Import ipython widgets
import json
import ipywidgets as widgets
import matplotlib.pyplot as plt
import numpy as np
# Set up the environment.
from IPython.display import display
from scipy.signal import spectrogram, welch
from scipy.signal.windows import gaussian
from qcodes import Instrument
from qblox_instruments import Cluster, PlugAndPlay
Scan For Devices
We scan for the available devices connected via ethernet using the Plug & Play functionality of the Qblox Instruments package (see Plug & Play for more info).
[2]:
# Scan for available devices and display
with PlugAndPlay() as p:
# get info of all devices
device_list = p.list_devices()
names = {
dev_id: dev_info["description"]["name"] for dev_id, dev_info in device_list.items()
}
ip_addresses = {
dev_id: dev_info["identity"]["ip"] for dev_id, dev_info in device_list.items()
}
# create widget for names and ip addresses
connect = widgets.Dropdown(
options=[(names[dev_id] + " @" + ip_addresses[dev_id], dev_id)
for dev_id in device_list.keys()],
description="Select Device",
)
display(connect)
Connect to Cluster
We now make a connection with the Cluster selected in the dropdown widget. We also define a function to find the modules we’re interested in. We select the readout and control module we want to use.
[ ]:
# Connect to device
dev_id = connect.value
# Close the chosen QCodes instrument as to prevent name clash.
try:
Instrument.find_instrument(names[dev_id]).close()
except KeyError:
pass
cluster = Cluster(name=names[dev_id], identifier=ip_addresses[dev_id], debug=True) # TODO remove debug
print(f"{connect.label} connected")
print(cluster.get_system_state())
[ ]:
def select_module_widget(device, select_all=False, select_qrm_type: bool=True, select_rf_type: bool=False):
"""Create a widget to select modules of a certain type
default is to show only QRM baseband
Args:
devices : Cluster we are currently using
select_all (bool): ignore filters and show all modules
select_qrm_type (bool): filter QRM/QCM
select_rf_type (bool): filter RF/baseband
"""
options = [[None, None]]
for module in device.modules:
if module.present():
if select_all or (module.is_qrm_type == select_qrm_type and module.is_rf_type == select_rf_type):
options.append(
[
f"{device.name} "
f"{module.short_name} "
f"({module.module_type}{'_RF' if module.is_rf_type else ''})",
module,
]
)
widget = widgets.Dropdown(options=options)
display(widget)
return widget
[ ]:
print("Select the readout module from the available modules:")
select_readout_module = select_module_widget(cluster, select_qrm_type=True, select_rf_type=False)
[ ]:
readout_module = select_readout_module.value
print(f"{readout_module} connected")
Reset the Cluster
We reset the Cluster to enter a well-defined state. Note that resetting will clear all stored parameters, so resetting between experiments is usually not desirable.
[ ]:
cluster.reset()
print(cluster.get_system_state())
Frequency sweeps
One of the most common experiments is to test the frequency response of the system, e.g. to find the resonance frequencies of a qubit or a resonator. For the purpose of this tutorial, we will sweep the full frequency range supported by the QRM. To improve accuracy we can use the maximum integration time and multiple averages. This does not change the overall measurement time much, as most of it is used for the setup.
[6]:
start_freq = -500e6
stop_freq = 500e6
n_averages = 10
MAXIMUM_SCOPE_ACQUISITION_LENGTH = 16384
In this tutorial, we will analyze the raw data measured by the scope acquisition of the QRM. For this we will define a simple helper function using scipy.signal.spectrogram and scipy.signal.welch. The spectrogram shows the frequency spectrum of the QRM output as a function of time, to visualize the frequency sweeps we are doing. Welch’s method is used to compute the input power as a function of frequency (power spectral density). This way we obtain the response of the system to find features of interest, e.g. a resonance.
[7]:
# Power as function of frequency and time by chunking the data
def plot_spectrogram(time_series: np.ndarray) -> None:
f_sample = 1e9 # All devices have 1 GSPS sample rate
fig, ax = plt.subplots(1, 2)
f, t, Sxx = spectrogram(time_series, f_sample, return_onesided=False, detrend=False)
idx = np.argsort(f)
f = f[idx] / 1e6
Sxx = Sxx[idx]
spec = ax[0].pcolormesh(t, f, Sxx, shading="auto", cmap="YlOrRd")
cb = fig.colorbar(spec)
cb.set_label("Power Spectral Density [V$^2$/Hz]")
ax[0].set_ylabel("Frequency [MHz]")
ax[0].set_xlabel("Time [s]")
f, Pxx = welch(time_series, f_sample, return_onesided=False, detrend=False)
idx = np.argsort(f)
f = f[idx] / 1e6
Pxx = Pxx[idx]
ax[1].semilogy(f, Pxx)
ax[1].set_xlabel("Frequency [MHz]")
ax[1].set_ylabel("Power Spectral Density [V$^2$/Hz]")
fig.tight_layout()
plt.show()
And two more helper functions for plotting the amplitude of an array of I, Q values and a scope acquisition:
[8]:
def plot_amplitude(x, I_data, Q_data):
amplitude = np.abs(I_data + 1j * Q_data)
plt.plot(x/1e6, amplitude)
plt.xlabel("Frequency [MHz]")
plt.ylabel("Integration [V]")
plt.show()
def plot_scope(trace, t_min:int, t_max:int):
x = np.arange(t_min, t_max)
plt.plot(x, np.real(trace[t_min:t_max]))
plt.plot(x, np.imag(trace[t_min:t_max]))
plt.ylabel("Scope [V]")
plt.xlabel("Time [ns]")
plt.show()
Setting up the QRM
We set up a modulated DC offset:
[9]:
readout_module.disconnect_outputs()
readout_module.disconnect_inputs()
# Configure channel map
readout_module.sequencer0.connect_sequencer("io0_1")
# Set DC Offset
readout_module.sequencer0.offset_awg_path0(1)
readout_module.sequencer0.offset_awg_path1(1)
# Enable modulation and demodulation. Note that the scope is not demodulated
readout_module.sequencer0.mod_en_awg(True)
readout_module.sequencer0.demod_en_acq(True)
# Enable hardware averaging for the scope
readout_module.scope_acq_avg_mode_en_path0(True)
readout_module.scope_acq_avg_mode_en_path1(True)
readout_module.sequencer0.integration_length_acq(MAXIMUM_SCOPE_ACQUISITION_LENGTH)
NCO sweep controlled by the host computer
As a baseline, we will run a simple frequency sweep controlled by the host computer using QCoDeS. We do this by setting a DC offset and modulating it with the NCO. This is quite slow, so we will only measure 200 steps to keep the measurement time reasonable.
[10]:
n_steps = 200
step_freq = (stop_freq - start_freq) / n_steps
print(f"Step size {step_freq/1e6} MHz")
nco_sweep_range = np.arange(start_freq, stop_freq, step_freq)
Step size 5.0 MHz
Now we set up a simple program that acquires data and averages. The frequency will be set later with the QCoDeS interface.
Note: While most operations and parameters are executed/updated on a 1 ns timegrid, the instructions that operate on the sequencer’s NCOs (e.g. set_freq, reset_ph, set_ph, set_ph_delta) are updated on a 4 ns timegrid.
[11]:
acquisitions = {"acq": {"num_bins": 1, "index": 0}}
# Sequence program.
slow_sweep = f"""
move {n_averages}, R0 # Average iterator.
avg_loop:
reset_ph
upd_param 200
acquire 0, 0, {MAXIMUM_SCOPE_ACQUISITION_LENGTH}
loop R0, @avg_loop
stop
"""
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": slow_sweep,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
file.close()
Next, we prepare the QRM for the measurement:
[12]:
readout_module.sequencer0.sequence("sequence.json")
Now we can run the frequency sweep. This is simply a loop where we set the frequency with QCoDeS and then run the program defined above. We measure the run time using the %%time
Jupyter magic command.
[13]:
%%time
data = []
for nco_val in nco_sweep_range:
# Set the frequency
readout_module.sequencer0.nco_freq(nco_val)
# Run the program
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, 1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
# Get acquisition list from instrument.
data.append(readout_module.get_acquisitions(0)["acq"])
# Clear acquisition data so we do not average the results from different frequencies
readout_module.sequencer0.delete_acquisition_data("acq")
CPU times: total: 2.58 s
Wall time: 10.1 s
Plotting the acquired integration data, we can see the frequency behavior of the QRM.
[14]:
I_data = (
np.asarray([d["acquisition"]["bins"]["integration"]["path0"][0] for d in data])
/ MAXIMUM_SCOPE_ACQUISITION_LENGTH
)
Q_data = (
np.asarray([d["acquisition"]["bins"]["integration"]["path1"][0] for d in data])
/ MAXIMUM_SCOPE_ACQUISITION_LENGTH
)
plot_amplitude(nco_sweep_range, I_data, Q_data)
We can see that the output amplitude decreases with frequency, this is expected due to the analog filters. We can also analyze the accumulated scope data with a spectrogram. This takes a few seconds, as there are 16384 data points per frequency step. Note that the time axis of the spectrogram refers to measurement time (16.4us * 200 steps \(\approx\) 3.3ms) and not the wall clock time, which is significantly longer.
[15]:
data_scope = (
np.asarray([d["acquisition"]["scope"]["path0"]["data"] for d in data]).flatten()
+ 1j
* np.asarray([d["acquisition"]["scope"]["path1"]["data"] for d in data]).flatten()
)
plot_spectrogram(data_scope)
Spectroscopy using Q1ASM
Now we will run the same spectroscopy experiment using Q1ASM to change the NCO frequency in real time. First, we set up the QRM for continuous wave output and binned acquisition with many bins. This is significantly faster than using QCoDeS. The maximum number of points that can be measured this way is 131072 per sequencer, which is the maximum number of bins.
The sequencer program can fundamentally only support integer values. However, the NCO has a frequency resolution of 0.25 Hz and supports \(10^9\) phase values. Therefore, frequencies in the sequencer program must be given as integer multiple of \(1/4\) Hz, and phases as integer multiple of \(360/10^9\) degree.
[16]:
n_steps = 200
step_freq = (stop_freq - start_freq) / n_steps
print(f"{n_steps} steps with step size {step_freq/1e6} MHz")
# Convert frequencies to multiples of 0.25 Hz
nco_int_start_freq = int(4 * start_freq)
nco_int_step_freq = int(4 * step_freq)
200 steps with step size 5.0 MHz
[17]:
acquisitions = {"acq": {"num_bins": n_steps, "index": 0}}
setup = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # frequency
move 0, R1 # step counter
"""
# To get a negative starting frequency, we substract a positive number from 0
if start_freq <= 0:
setup += f"""
sub R0, {-nco_int_start_freq}, R0
"""
else:
setup += f"""
add R0, {nco_int_start_freq}, R0
"""
spectroscopy = (
setup
+ f"""
reset_ph
set_freq R0
upd_param 200
nco_set:
set_freq R0 # Set the frequency
add R0, {nco_int_step_freq}, R0 # Update the frequency register
upd_param 200 # Wait for time of flight
acquire 0, R1, {MAXIMUM_SCOPE_ACQUISITION_LENGTH}
add R1, 1, R1
nop
jlt R1, {n_steps}, @nco_set # Loop over all frequencies
loop R2, @avg_loop
stop # Stop
"""
)
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": spectroscopy,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
Now we prepare the QRM for measurement.
[18]:
readout_module.sequencer0.sequence("sequence.json")
[19]:
%%time
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, 1)
data = readout_module.get_acquisitions(0)["acq"]
CPU times: total: 156 ms
Wall time: 178 ms
Note that the same measurement as before is now two orders of magnitude faster. If we plot the integrated data, we get the same results as before.
[20]:
# For plotting, convert the NCO integer values back to frequencies
nco_sweep_range = (np.arange(n_steps)*nco_int_step_freq + nco_int_start_freq) / 4.0
I_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path0"])
/ MAXIMUM_SCOPE_ACQUISITION_LENGTH
)
Q_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path1"])
/ MAXIMUM_SCOPE_ACQUISITION_LENGTH
)
plot_amplitude(nco_sweep_range, I_data, Q_data)
NCO input delay compensation
By default, the input and output of the QRM are multiplied with the same NCO value. As the output path has a time of flight of about 146 ns between the NCO and playback, this means that there is a short time window after frequency/phase updates where demodulation is updated, but playback is still using the old value. There is also always a (fixed) relative phase between playback and demodulation. We can showcase this by using a similar program as before, but with less points, so that the frequency steps are more clearly visible.
[21]:
n_steps = 20
n_averages = 1000
step_freq = (stop_freq - start_freq) / n_steps
print(f"{n_steps} steps with step size {step_freq/1e6} MHz")
# Convert frequencies to multiples of 0.25 Hz
nco_int_start_freq = int(4 * start_freq)
nco_int_step_freq = int(4 * step_freq)
# For plotting, convert the NCO integer values back to frequencies
nco_sweep_range = np.arange(nco_int_start_freq, 4 * stop_freq, nco_int_step_freq) / 4.0
20 steps with step size 50.0 MHz
To make the effect of NCO delay compensation more apparent, we modify the spectroscopy program for short integration time and acquire immediately after the frequency update, without waiting for time of flight. This means that the output at the new frequency only arrives at the input AFTER integration in the current loop iteration has finished. Without further modifications of the program this leads to an off-by-one error. Therefore, we increase the frequency as the first step in the loop.
[22]:
acquisitions = {"acq": {"num_bins": n_steps, "index": 0}}
setup = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # frequency
move 0, R1 # step counter
"""
# To get a negative starting frequency, we substract a positive number from 0
if start_freq <= 0:
setup += f"""
sub R0, {-nco_int_start_freq}, R0
"""
else:
setup += f"""
add R0, {nco_int_start_freq}, R0
"""
spectroscopy = (
setup
+ f"""
reset_ph
set_freq R0
upd_param 200
nco_set:
# Due to time of flight, the new frequency will only arrive at the input AFTER integration is done
# Therefore, we already increase the frequency before the first measurement.
add R0, {nco_int_step_freq}, R0
nop
set_freq R0
# we removed upd_param, so that acquisition starts the moment the frequency is updated
acquire 0, R1, 1200 # Update the NCO and immediately acquire
add R1, 1, R1
nop
jlt R1, {n_steps}, @nco_set # Loop over all frequencies
loop R2, @avg_loop
stop # Stop
"""
)
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": spectroscopy,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
As a baseline, we will do a measurement with delay compensation disabled.
[23]:
readout_module.sequencer0.sequence("sequence.json")
readout_module.sequencer0.integration_length_acq(140)
readout_module.sequencer0.nco_prop_delay_comp_en(False)
[24]:
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
data = readout_module.get_acquisitions(0)["acq"]
I_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path0"])
/ 140
)
Q_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path1"])
/ 140
)
plot_amplitude(nco_sweep_range, I_data, Q_data)
Even though we only measured a small number of points, we can see that this is not compatible with the previous spectroscopy measurements. What happened is that set_freq
updates the NCO frequency immediately. However, there is a time of flight of about 146 ns between the NCO and the output of the device. Thus, the signal will be demodulated at \(f_0 + 100\) MHz immediately after set_freq
, but the incoming signal is still modulated at \(f_0\) for another 146 ns - longer than the
integration time chosen above. The integrated signal will therefore be approximately zero.
Now we run the same experiment again, with delay compensation enabled.
[25]:
readout_module.sequencer0.sequence("sequence.json")
readout_module.sequencer0.nco_prop_delay_comp_en(True)
This ensures that, for demodulation, the NCO only updates after the time of flight, i.e. that frequency and phase of modulation and demodulation always match.
[26]:
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
data = readout_module.get_acquisitions(0)["acq"]
I_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path0"])
/ 140
)
Q_data = (
np.asarray(data["acquisition"]["bins"]["integration"]["path1"])
/ 140
)
amplitude = np.abs(I_data + 1j * Q_data)
plot_amplitude(nco_sweep_range, I_data, Q_data)
We can see that modulation and demodulation frequency now match, producing similar results as the spectroscopy measurements before.
Fast chirped pulses using Q1ASM
Now we will run a fast frequency sweep using Q1ASM to change the NCO frequency in real time during playback. This type of pulse is also called a chirp. First, we set up the QRM for continuous wave output and a single scope acquisition. This is significantly faster than spectroscopy, but also limits the maximum number of points we can measure in a single program. The total duration of the sweep must be 16384 ns or less, as that is the maximum length of a scope acquisition.
The sequencer program can fundamentally only support integer values. However, the NCO has a frequency resolution of 0.25 Hz and supports \(10^9\) phase values. Therefore, frequencies in the sequencer program must be given as an integer multiple of \(1/4\) Hz, and phases as an integer multiple of \(360/10^9\) degrees.
[27]:
step_time = 44 # Time per frequency step in ns. We can reduce this, but the program needs to be changed. See next section
n_steps = int(16384 / step_time)
n_averages = 10
step_freq = (stop_freq - start_freq) / n_steps
print(f"{n_steps} steps with step size {step_freq/1e6} MHz")
# Convert frequencies to multiples of 0.25 Hz
nco_int_start_freq = int(4 * start_freq)
nco_int_step_freq = int(4 * step_freq)
# For plotting, convert the NCO integer values back to frequencies
nco_sweep_range = np.arange(nco_int_start_freq, 4 * stop_freq, nco_int_step_freq) / 4.0
372 steps with step size 2.6881720430107525 MHz
Now, we write a Q1ASM program that quickly changes the NCO’s frequency, converting the continuous sine output into a chirp.
Internally, the processor stores negative values using two’s complement. This has some implications for our program: - We cannot directly store a negative value in a register. Substracting a larger value from a smaller one works as expected though. - Immediate values are handled by the compiler, i.e. set_freq-100
gives the expected result of -25 Hz. - Comparisons (jlt, jge
) with registers storing a negative value do not work as
expected, as the smallest negative number is larger than the largest positive number. To keep the program general we should therefore use loop
instead.
[28]:
acquisitions = {"acq": {"num_bins": 1, "index": 0}}
setup = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # frequency
move {n_steps}, R1 # n_steps
"""
# To get a negative starting frequency, we substract a positive number from 0
if start_freq <= 0:
setup += f"""
sub R0, {-nco_int_start_freq}, R0
"""
else:
setup += f"""
add R0, {nco_int_start_freq}, R0
"""
# Play a chirped pulse
chirp = (
setup
+ f"""
reset_ph
set_freq 0
upd_param 200
acquire 0,0,4 # Start acquisition. This is not blocking
nco_set:
set_freq R0 # Set the frequency
add R0,{nco_int_step_freq}, R0 # Update the frequency register
upd_param {step_time}
loop R1, @nco_set # Loop over all frequencies
wait 10000
loop R2, @avg_loop
stop # Stop
"""
)
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": chirp,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
[29]:
readout_module.sequencer0.sequence("sequence.json")
readout_module.sequencer0.integration_length_acq(MAXIMUM_SCOPE_ACQUISITION_LENGTH)
Run the program
[30]:
%%time
readout_module.sequencer0.nco_freq(0)
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
data = readout_module.get_acquisitions(0)["acq"]
CPU times: total: 15.6 ms
Wall time: 49.6 ms
Note that this is significantly faster than standard spectroscopy with Q1ASM with a larger number of points. For this measurement, we only use the scope acquisition data. We can analyze it again with a spectrogram.
[31]:
trace = np.array(data["acquisition"]["scope"]["path0"]["data"]) + 1j * np.array(
data["acquisition"]["scope"]["path1"]["data"]
)
plot_spectrogram(trace)
Note the difference in timescale to before. In the spectrogram we can see the intended spectrum of the chirp. And finally, we can visualize the chirp pulse. For better clarity, we show the low frequency parts around 8400ns.
[32]:
plot_scope(trace, 8350, 9000)
Timings of the Q1 and realtime processors
The sequencer has a real-time pipeline that generates the output and a classical pipeline responsible for logic and filling the queue of the real-time pipeline. This queue is 32 instructions long and starts pre-filled when the sequencer is started. If the runtime of classical instructions is shorter than the corresponding real-time instructions, the sequencer will stop. See also in the documentation of the sequencer.
We can see this by running the same program as before, but with reduced time between frequency steps:
[33]:
step_time = 40 # this will cause stalling
n_steps = int(16384 / step_time)
step_freq = (stop_freq - start_freq) / n_steps
print(f"{n_steps} steps with step size {step_freq/1e6} MHz")
# Convert frequencies to multiples of 0.25 Hz
nco_int_start_freq = int(4 * start_freq)
nco_int_step_freq = int(4 * step_freq)
# For plotting, convert the NCO integer values back to frequencies
nco_sweep_range = np.arange(nco_int_start_freq, 4 * stop_freq, nco_int_step_freq) / 4.0
409 steps with step size 2.4449877750611244 MHz
[34]:
acquisitions = {"acq": {"num_bins": 1, "index": 0}}
setup = f"""
move {n_averages}, R2
avg_loop:
move {n_steps}, R1 # n_steps
move 0, R0 # frequency
nop
"""
# To get a negative starting frequency, we substract a positive number from 0
if start_freq <= 0:
setup += f"""
sub R0, {-nco_int_start_freq}, R0
"""
else:
setup += f"""
add R0, {nco_int_start_freq}, R0
"""
# Play a chirped pulse
chirp = (
setup
+ f"""
reset_ph
set_freq 0
upd_param 200
acquire 0,0,4 # Start acquisition. This is not blocking
nco_set:
set_freq R0 # Set the frequency
add R0,{nco_int_step_freq}, R0 # Update the frequency register
upd_param {step_time}
loop R1, @nco_set # Loop over all frequencies
wait 10000
loop R2, @avg_loop
stop # Stop
"""
)
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": chirp,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
file.close()
[35]:
readout_module.sequencer0.sequence("sequence.json")
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
data = readout_module.get_acquisitions(0)["acq"]
As can be seen from the red LEDs on the front of your Cluster, the Q1 processor has stalled, and the program stopped.
[36]:
print(readout_module.sequencer0.get_sequencer_state())
Status: STOPPED, Flags: FORCED_STOP, SEQUENCE_PROCESSOR_RT_EXEC_COMMAND_UNDERFLOW, ACQ_SCOPE_DONE_PATH_0, ACQ_SCOPE_DONE_PATH_1, ACQ_BINNING_DONE
We can also see on the scope that the chirp has been stopped prematurely.
[37]:
trace = np.array(data["acquisition"]["scope"][f"path0"]["data"]) + 1j * np.array(
data["acquisition"]["scope"][f"path1"]["data"]
)
plot_spectrogram(trace)
Before continuing, we clear the flags on the qrm:
[38]:
cluster.clear()
If we want to the chirp to use as many updates as possible, we need to unroll the loop. This way, we can reduce the time per frequency step down to 24ns: set_freq, upd_param
both take 4ns and add
takes 12ns on the Q1 processor for a total of 20ns per frequency step.
[39]:
step_time = 20
n_steps = int(16384 / step_time)
step_freq = (stop_freq - start_freq) / n_steps
print(f"{n_steps} steps with step size {step_freq/1e6} MHz")
# Convert frequencies to multiples of 0.25 Hz
nco_int_start_freq = int(4 * start_freq)
nco_int_step_freq = int(4 * step_freq)
# For plotting, convert the NCO integer values back to frequencies
nco_sweep_range = np.arange(nco_int_start_freq, 4 * stop_freq, nco_int_step_freq) / 4.0
819 steps with step size 1.221001221001221 MHz
This does not leave room for a loop, which would take an additional 24ns. However, we can use the instruction memory of the Q1 processor:
[40]:
chirp = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # frequency
nop
"""
# To get a negative starting frequency, we substract a positive number from 0
if start_freq <= 0:
chirp += f"""
sub R0, {-nco_int_start_freq}, R0
"""
else:
chirp += f"""
add R0, {nco_int_start_freq}, R0
"""
chirp += f"""
reset_ph
set_freq 0
upd_param 200
acquire 0,0,4 # Start acquisition. This is not blocking
"""
# unroll the loop into individual commands
for _ in range(n_steps):
chirp += f"""
set_freq R0 # Set the frequency
add R0,{nco_int_step_freq}, R0 # Update the frequency register
upd_param {step_time}
"""
chirp += """
wait 10000
loop R2, @avg_loop
stop # Stop
"""
# Add sequence to single dictionary and write to JSON file.
sequence = {
"waveforms": {},
"weights": {},
"acquisitions": acquisitions,
"program": chirp,
}
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(sequence, file, indent=4)
file.close()
[41]:
readout_module.sequencer0.sequence("sequence.json")
Now we execute the program and plot the spectrogram:
[42]:
%%time
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
data = readout_module.get_acquisitions(0)["acq"]
CPU times: total: 15.6 ms
Wall time: 45.1 ms
Note that the execution time is comparable to the other chirped measurements, but with more than double the number of points.
[43]:
trace = np.array(data["acquisition"]["scope"][f"path0"]["data"]) + 1j * np.array(
data["acquisition"]["scope"][f"path1"]["data"]
)
plot_spectrogram(trace)
Phase updates
Virtual Z gates
In addition to fast frequency updates, the sequencer also supports real-time changes of the NCO phase. In particular for superconducting qubits, this can be used for a so-called virtual \(Z\) gate, see McKay et al. (2016). The virtual \(Z\) gate is a change of reference frame rather than a physical operation. Therefore, it is instantaneous and near perfect - the dominant error being that the NCO has a finite resolution of \(10^9\) different phases. Below, we will demonstrate how to to use a virtual Z to use the same pulse for both \(X\) and \(Y\) rotations.
As the sequencer internally only supports integer values, we must first convert the phase into an integer multiple of \(360/10^{9}\) degree:
[44]:
int_90 = int(90 * (1e9 / 360))
int_270 = int(270 * (1e9 / 360))
[45]:
# Waveforms
waveform_len = 1000
waveforms = {
"gaussian": {
"data": gaussian(waveform_len, std=0.133 * waveform_len).tolist(),
"index": 0,
},
}
# Acquisitions
acquisitions = {"scope": {"num_bins": 1, "index": 0}}
# Program
virtual_z = f"""
acquire 0,0,4
reset_ph
play 0,0,{waveform_len} # X90
# This is equivalent to Y90, but uses the same waveform as X90
set_ph_delta {int_90} # Z90
play 0,0,{waveform_len} # X90
set_ph_delta {int_270} # Z-90
play 0,0,{waveform_len} # X90
stop
"""
# Write sequence to file.
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(
{
"waveforms": waveforms,
"weights": {},
"acquisitions": acquisitions,
"program": virtual_z,
},
file,
indent=4,
)
file.close()
For this experiment, we reset the QRM and enable modulation at a low frequency so that the effects are easily visible (without offsets).
[46]:
# Program sequencers.
cluster.reset()
readout_module.sequencer0.sequence("sequence.json")
readout_module.disconnect_outputs()
readout_module.disconnect_inputs()
# Configure channel map
readout_module.sequencer0.connect_sequencer("io0_1")
readout_module.sequencer0.nco_freq(3e6)
# Enable modulation
readout_module.sequencer0.mod_en_awg(True)
readout_module.sequencer0.demod_en_acq(True)
# Enable hardware averaging for the scope
readout_module.scope_acq_avg_mode_en_path0(True)
readout_module.scope_acq_avg_mode_en_path1(True)
readout_module.sequencer0.integration_length_acq(MAXIMUM_SCOPE_ACQUISITION_LENGTH)
Now we can run the program and look at the scope acquisition.
[47]:
# Start the sequence
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop
readout_module.get_acquisition_state(0, timeout=1)
# Get acquisition data
readout_module.store_scope_acquisition(0, "scope")
acq = readout_module.get_acquisitions(0)
trace = np.asarray(
acq["scope"]["acquisition"]["scope"]["path0"]["data"]
) + 1j * np.asarray(acq["scope"]["acquisition"]["scope"]["path1"]["data"])
plot_scope(trace, 0, 4000)
Chirped pulses using the phase update
As an exercise combining the concepts from this notebook, we can also create a chirp using only phase updates. This is purely educational and should not be used in an experiment. Again, we do not use a loop, and use the instruction memory instead to make the step size smaller.
[48]:
n_averages = 100
n_steps = int(16384 / (20))
acquisitions = {"acq": {"num_bins": 1, "index": 0}}
phase_chirp = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # phase update step size
reset_ph
set_freq 0
upd_param 200
acquire 0,0,4 # Start acquisition. This is not blocking
nco_set:
"""
# step the phase with increasing step size
for _ in range(n_steps):
phase_chirp += f"""
set_ph_delta R0
upd_param 20
add R0, {int(1e9/(4*n_steps))}, R0 # increase the 'frequency'
"""
phase_chirp += """
wait 10000
loop R2, @avg_loop
stop # Stop
"""
# Write sequence to file.
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(
{
"waveforms": waveforms,
"weights": {},
"acquisitions": acquisitions,
"program": phase_chirp,
},
file,
indent=4,
)
file.close()
We can run this with the same settings as the chirps before:
[49]:
readout_module.sequencer0.sequence("sequence.json")
# Set DC Offset
readout_module.sequencer0.offset_awg_path0(1)
readout_module.sequencer0.offset_awg_path1(1)
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
data = readout_module.get_acquisitions(0)["acq"]
In the spectrogram we can see a slow frequency sweep - plus high frequency components. The reason for those is easily visible in the scope, the “sine” wave is not smooth, but instead made up of many square pulses (as expected).
[50]:
trace = np.array(data["acquisition"]["scope"]["path0"]["data"]) + 1j * np.array(
data["acquisition"]["scope"]["path1"]["data"]
)
plot_spectrogram(trace)
plot_scope(trace, 0, 2000)
Using registers, we can also do negative phase steps:
[51]:
n_averages = 100
n_steps = int(16384 / (20))
acquisitions = {"acq": {"num_bins": 1, "index": 0}}
phase_chirp = f"""
move {n_averages}, R2
avg_loop:
move 0, R0 # phase update step size
reset_ph
upd_param 200
set_freq 0
acquire 0,0,4 # Start acquisition. This is not blocking
nco_set:
"""
# step the phase with increasing (negative) step size
for _ in range(n_steps):
phase_chirp += f"""
set_ph_delta R0
upd_param 20
sub R0, {int(1e9/(4*n_steps))}, R0 # increase the step size ('frequency')
"""
phase_chirp += """
wait 10000
loop R2, @avg_loop
stop # Stop
"""
# Write sequence to file.
with open("sequence.json", "w", encoding="utf-8") as file:
json.dump(
{
"waveforms": waveforms,
"weights": {},
"acquisitions": acquisitions,
"program": phase_chirp,
},
file,
indent=4,
)
file.close()
readout_module.sequencer0.sequence("sequence.json")
readout_module.arm_sequencer(0)
readout_module.start_sequencer()
# Wait for the sequencer to stop with a timeout period of one minute.
readout_module.get_acquisition_state(0, timeout=1)
# Move acquisition data from temporary memory to acquisition list.
readout_module.store_scope_acquisition(0, "acq")
data = readout_module.get_acquisitions(0)["acq"]
trace = np.array(data["acquisition"]["scope"]["path0"]["data"]) + 1j * np.array(
data["acquisition"]["scope"]["path1"]["data"]
)
plot_spectrogram(trace)
plot_scope(trace, 0, 2500)
Stop
Finally, let’s stop the playback and close the instrument connection. One can also display a detailed snapshot containing the instrument parameters before closing the connection by uncommenting the corresponding lines.
[52]:
# Stop both sequencers.
readout_module.stop_sequencer()
# Print status of both sequencers (should now say it is stopped).
print(readout_module.get_sequencer_state(0))
print(readout_module.get_sequencer_state(1))
print()
# Uncomment the following to print an overview of the instrument parameters.
# Print an overview of the instrument parameters.
# print("Snapshot:")
# readout_module.print_readable_snapshot(update=True)
# Close the instrument connection.
Instrument.close_all()
Status: STOPPED, Flags: FORCED_STOP, ACQ_SCOPE_DONE_PATH_0, ACQ_SCOPE_OVERWRITTEN_PATH_0, ACQ_SCOPE_DONE_PATH_1, ACQ_SCOPE_OVERWRITTEN_PATH_1, ACQ_BINNING_DONE
Status: STOPPED, Flags: FORCED_STOP